Alarm Threshold Registers
There are seven alarm threshold registers that store
overtemperature ALERT and OVERT threshold values.
Five of these registers are dedicated to store one local
alert temperature threshold limit and four remote alert
temperature threshold limits (see the ALERT Interrupt
Mode section). The remaining two registers are dedi-
cated to remote channels 1 and 4 to store overtempera-
ture threshold limits (see the OVERT Overtemperature
Alarms section). Access to these registers is provided
through the SMBus interface.
ALERT Interrupt Mode
An ALERT interrupt occurs when the internal or external
temperature reading exceeds a high-temperature limit
(user programmable). The ALERT interrupt output signal
can be cleared by reading the status register(s) associ-
ated with the fault(s) or by successfully responding to an
alert response address transmission by the master. In
both cases, the alert is cleared but is reasserted at the
end of the next conversion if the fault condition still
exists. The interrupt does not halt automatic conversions.
The ALERT output is open drain so that multiple devices
can share a common interrupt line. All ALERT interrupts
can be masked using the configuration 3 register. The
POR state of these registers is shown in Table 1.
5-Channel Precision Temperature Monitor
_______________________________________________________________________________________   9
SMBCLK
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
A
B
C
D
E    F
G
H
I
J
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
tHIGH
t
SU:DAT
t
SU:STO
t
BUF
L
M
K
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
Figure 3. SMBus Write Timing Diagram
SMBCLK
A
B
C
D
E   F
G
H
I   J  K
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
HD:DAT
t
SU:STO
t
BUF
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
L
M
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
Figure 4. SMBus Read Timing Diagram
相关PDF资料
MAX6626RMTT+T IC TEMP SENSOR I2C 6-TDFN
MAX6627MKA#TG16 IC TEMP SENSOR DGTL SOT23-8
MAX6636UP9A+T IC PREC TEMP MONITOR 7CH 20TSSOP
MAX6639FATE+ IC 2CH TEMP MONITOR 16TQFN
MAX6641AUB92+ IC TEMP MONITOR SMBUS 10UMAX
MAX6642ATT94+T IC TEMP SENSOR SMBUS 6TDFN
MAX6643LBFAEE+ IC CTLR PWM FAN-SPEED 16QSOP
MAX6649MUA/V+ IC SENSOR REMOTE SMBUS 8UMAX
相关代理商/技术参数
MAX66240ETA+ 制造商:Maxim Integrated Products 功能描述:HF 4KBIT SHA-256 SECURE EEPROM - Rail/Tube
MAX66240ETA+T 制造商:Maxim Integrated Products 功能描述:HF 4KBIT SHA-256 SECURE EEPROM - Tape and Reel
MAX6625PMTT+ 制造商:Maxim Integrated Products 功能描述:TEMP SENSOR DGTL I2C 6TDFN EP - Rail/Tube
MAX6625PMTT+T 功能描述:板上安装温度传感器 9-Bit/12-Bit Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6625PMUT 制造商:Maxim Integrated Products 功能描述:9-BIT TEMPERATURE SENSOR W/ I2CC-COMPATIBLE S - Rail/Tube
MAX6625PMUT+T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6625PMUT-T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6625RMTT+ 制造商:Maxim Integrated Products 功能描述:TEMP SENSOR DGTL I2C 6TDFN EP - Rail/Tube